The NEMS application is highly configurable. During build-time, i.e. when the NEMS executable is being compiled and linked, choices are made as to which model and mediator components are built into the system. The built-in components become accessible during run-time, allowing the execution of different run configurations without the need to rebuild NEMS.
Often the build and run configurability of NEMS is hidden from the user by application or test scripts. However, there are times where it is useful to understand the technical details on the level of the NEMS executable.
During run-time of the NEMS executable, it accesses a file called nems.configure, which it expects to find in the run directory. This file specifies the dynamic component selection, and the exact run sequence to be used. Only models built into the executable at build-time are accessible during run-time. An error will be triggered if an unavailable model is selected in nems.configure. The component selection is based on two variables:
xxx_model: abc xxx_petlist_bounds: lower upper
Here xxx
can be atm
, ocn
, ice
, ipm
, med
. The abc
stands for the actual instance name, e.g. fv3
or mom6
. The lower and upper bounds of the petList specification are integer PET numbers.
The specification of the run sequence provides the flexibility needed to cover different coupling scenarios. The format is line based between special tags:
runSeq:: line1 line2 ... lineN ::
There are a number of format options for each line:
@
symbol, followed immediatly by the number of seconds of the associated time step.@
symbol on a line.RUN
method of model component xxx
is called by specifying just xxx
on a line. The supported values of xxx
are the same as for the model specification above. A specific RUN phase can be provided by adding the phase label to the same line, following the model string.xxx
to component yyy
is specified by a line like this: xxx -> yyy
. An additional argument on the same line can be used to specify connection options for all of the field handled by the connector. The format and supported values of the connection options is documented in the NUOPC reference manual.A very simple run sequence is running only the atmospheric uncoupled model. The run sequence looks like:
# Run Sequence # runSeq:: ATM ::
A more complex example is when components are exchanging information at two time scales:
# Run Sequence # runSeq:: @7200.0 OCN -> MED MED MedPhase_slow MED -> OCN OCN @3600.0 MED MedPhase_fast_before MED -> ATM ATM ATM -> MED MED MedPhase_fast_after @ @ ::
Anything on a line after the #