NCEPLIBS-w3emc  2.9.3
w3fa01.f
Go to the documentation of this file.
1 C> @file
2 C> @brief Compute lifting condendsation level.
3 C> @author James Howcroft @date 1979-07-01
4 
5 C> Given the pressure, temperature and relative humidity of
6 C> an air parcel at some point in the atmosphere, calculate the
7 C> dewpoint temperature and the pressure and temperature of the
8 C> lifting condensation level.
9 C>
10 C> Program history log:
11 C> - James Howcroft 1979-07-01
12 C> - Ralph Jones 1989-01-24 Change to microsoft fortran 4.10.
13 C> - Ralph Jones 1990-06-11 Change to sun fortran 1.3.
14 C> - Ralph Jones 1991-03-29 Convert to silicongraphics fortran.
15 C> - Ralph Jones 1993-03-29 Add save statement.
16 C> - Ralph Jones 1995-09-25 Put in cray w3 library.
17 C>
18 C> @param[in] P Parcel pressure in millibars.
19 C> @param[in] T Parcel temperature in degrees celsius.
20 C> @param[in] RH Parcel relative humidity in percent.
21 C> @param[out] TD Dewpoint temperature in degrees celsius.
22 C> @param[out] PLCL Pressure of LCL in millibars.
23 C> @param[out] TLCL Temperature at LCL in degrees celsius.
24 C>
25 C> @author James Howcroft @date 1979-07-01
26  SUBROUTINE w3fa01(P,T,RH,TD,PLCL,TLCL)
27 C
28  SAVE
29 C
30 C DEFINITION OF THE POTENTIAL TEMPERATURE
31 C
32  potemp(t,p) = (t+273.16)*((1000./p)**0.2857)
33 C
34 C TETENS FORMULA WITH NATURAL BASE
35 C
36  vapres(t) = 6.11*exp((17.2694*t)/(t+237.3))
37 C
38 C BEGIN
39 C
40  IF (rh.LT.100) GO TO 10
41  plcl = p
42  tlcl = t
43  td = t
44  GO TO 40
45 C
46 C CALCULATE DEW POINT FROM RH AND T
47 C
48  10 CONTINUE
49  ar = alog(rh*0.01)/17.269
50  td = (-237.3*(ar+1.0)*t - ar*237.3**2)/(ar*t+237.3*(ar-1.0))
51  e = vapres(td)
52  w = (0.622*e)/(p-e)
53  theta = potemp(t,p)
54 C
55 C DO STACKPOLE'S THING AS IN JOUR APPL MET, VOL 6, PP 464-467.
56 C
57  eps = 0.1
58  cges = 0.5
59 C
60 C CONSTANTS -35.86 = 237.30 - 273.16
61 C 2048.7 = 273.16 * 7.50
62 C
63  pges = (((cges*(-35.86)+2048.7)/(theta*(7.5-cges)))**3.5)*1000.
64 C
65 C START ITERATION.
66 C
67  20 CONTINUE
68  cges = alog10((pges*w)/(6.11*(0.622+w)))
69  plcl = (((cges*(-35.86)+2048.7)/(theta*(7.5-cges)))**3.5)*1000.
70  IF (abs(plcl-pges) .LT. eps) GO TO 30
71  pges = plcl
72  GO TO 20
73 C
74  30 CONTINUE
75  tlcl = (cges * 237.3) / (7.5 - cges)
76 C
77 C FALL THRU WITH P,T OF THE LIFTED CONDENSATION LEVEL.
78 C
79  40 CONTINUE
80  RETURN
81  END
w3fa01
subroutine w3fa01(P, T, RH, TD, PLCL, TLCL)
Given the pressure, temperature and relative humidity of an air parcel at some point in the atmospher...